ShippedLive in VulcanOps today.

Fireground Scene: spot, supply and pump pressure before arrival

The Fireground Scene tab shows engine and aerial placement, the water supply lay and pump pressures for the call's building, worked out when the call is dispatched.

Fireground Scene: spot, supply and pump pressure before arrival: screenshot

The old way

A house fire is dispatched. The first engine rolls with an address and not much else. The officer builds a picture from memory of the street, maybe a pre-plan binder, maybe a look at a map on a phone. The driver wonders where the hydrant is. The pump operator does the pressure math in their head or from a card taped to the panel. The aerial crew finds out about the wires and the tree when they pull in and start to set the outriggers.

Some of that works because experienced people carry a lot in their heads. It works less well at 0300, with a new driver, or on a street nobody has been down in a year.

Why it was broken

The work gets done on scene, with the clock running and the radio busy. Each piece waits on the one before it:

  • The hydrant gets picked after the engine has already stopped.
  • A far hydrant or one past the building means a reverse lay that someone has to think through while the first line is waiting.
  • Pump pressure depends on the fire floor and the lay, and hand calculation under stress invites mistakes.
  • Aerial reach, wires, trees and soft ground are found by looking up and around after the rig is parked.
  • Each rig and each member may be working from a slightly different picture.

How we re-thought it

The Fireground Scene is a tab on the active fire incident. The scene is computed once when the call is dispatched, stored with the call and served instantly, so it is usually ready before anyone opens the incident. Recalculate forces a refresh if something changes.

It draws a sketch of the building with sides A to D, the aerial's reach and outriggers, the hydrant and supply lay, and the attack line. It shows where the first engine and aerial should set up, and checks for wires, trees and soft ground. It lists the order of work: supply first, then the FDC, then the attack. For each fire floor it shows the pump pressure and flow for the first line.

The AI work is in doing the planning and the arithmetic ahead of time. It picks a hydrant, plans a forward lay, or a reverse lay with the second engine when the hydrant is far or past the building. A reverse lay can also be requested in one press, without hand calculation. On a building set far back, the plan can put the trucks in a driveway and work the ladder, line and supply from there. The first engine comes from CAD unit times ahead of seats, and the default aerial is shown labelled not responding when it is not.

Every plan shows its work and its assumptions, so an officer can see why a number was chosen and check it against what they see. Plans follow the department's own unit set-up and attack tactics order. Look Around views of sides B, A and D are there, and in New Jersey the sketch uses NJ Office of GIS 6-inch orthophotos.

The officer's size-up always wins. This is decision support.

What it means for your department

The officer in the engine can check the aerial spot and wire or tree conflicts before arrival. The pump operator can read the pressure and order of work instead of building them from scratch. If the crew sees something different, they ask for a reverse lay or recalculate.

Everyone on the call sees the same plan, on the web, phone and station screens. Members, officers, chiefs and admins can all open it. The plan is a starting point to confirm or change, not a script.

All units — respond

Bring your whole department
onto one platform.

See VulcanOps run a real day — incidents, ePCR, scheduling, training, and community — in one live demo.